= 35 ve 3) Complete Table I, cross. referencing it to the numbers assigned on the Dust Collector Data Sheet. Please include a general flow sheet depicting the operations in Table I and showing points of dust control. 4) Are all fibre separators provided with a final collector on the exhaust gas? If no, provide emission data from the fibre separator. All air used in fibre separation and other process operations is treated by fabric filtration. 5) Open Pit Operation (Present) Equipment No.In ‘| Type Capacity Dust Control | Gal. Fuel Use Yes/No Used/Yr. ° — —————— , ES — RP electyic 11% yds Shovels 3 4% yds 100,000 il diese 314 vds. 5 diese 75 ton 12 diese 50 ton 500,000 6) Are haulage roads wetted for dust control? What wetting agent is used? No. Conditions are normally snow covered or wet, roads only being dusty occasionally between June and September. 7) Tailings Disposal Area Capacity of Disposal Area (Acres) Size of Dump (Acres) Elevation (ft. above grade) 14,000 Distance From (ft.) Mine Mill Adjacent Townsite 1 0001 4